Ultrasonic Scanning of Full Scale RC Beam-Column Joints of NPP Structures
IR@SERC: CSIR-Structural Engineering Research Centre, Chennai
View Archive InfoField | Value | |
Title |
Ultrasonic Scanning of Full Scale RC Beam-Column Joints of NPP Structures
|
|
Creator |
Thandavamoorthy, T.S.
Vimalanandam, V. Anandavalli, N. Reddy, G.R. Kushwaha, H.S. |
|
Subject |
Ultrasonic scanning
Ful scale RC beam-column joints NPP structures Seismic resistance design |
|
Description |
T-joint specimen was tested under monotonic loading upto failure. The paper presents in detail the concreting of the specimen with strict quality control and health monitoring with ultrasonic scanning before and after testing. Discussion on the extent of damage to concrete and consequent reduction in strength is also included in the paper.
|
|
Date |
2009
2009 2003 |
|
Type |
Conference paper
|
|
Identifier |
Proceedings of the International Conference on Recent Trends in Concrete Technology and Structures, Coimbatore, India, 10-12 September, 2003, p.157-166. Organised by Department of Civil Engineering, Kumaraguru College of Technology, Coimbatore.
http://hdl.handle.net/123456789/236 |
|
Language |
en
|
|