Repair of Corrosion-Damaged Columns with FRP Wraps
IR@SERC: CSIR-Structural Engineering Research Centre, Chennai
View Archive InfoField | Value | |
Title |
Repair of Corrosion-Damaged Columns with FRP Wraps
|
|
Creator |
Bharatkumar, B.H.
Krishnamoorthy, T.S. Lakshmanan, N. Balasubramanian, K. Ramesh, G. Sundar Kumar, S. Daniel Ronald Joseph, J. |
|
Subject |
Corrosion damaged
FRP Reinforced Corrosion |
|
Description |
One of the major durability problems is the rebar corrosion in concrete. This paper presents
the results of an experimental investigation on the repair of corroded reinforced concrete with
fibre reinforced polymer (FRP) wraps. Eight RC columns of size 150 x 150 x 700mm were
cast and four of them were subjected to accelerated corrosion test. After exposing the columns
for 30 days of accelerated corrosion, specimens were repaired using CFRP and GFRP
wrapping. The performance of FRP wrapping on strength enhancement under compressive
load is evaluated.
|
|
Date |
2009
2009 2008 |
|
Type |
Conference paper
|
|
Identifier |
Proceedings of the Sixth Structural Engineering Convention, SEC 2008, 18-20 December 2008, p.1253-1260. Jointly Organised by Structural Engineering Research Centre, Indian Institute of Technology, Anna university, Chennai.
http://hdl.handle.net/123456789/269 |
|
Language |
en
|
|