Title Suggested Revisions to Basic Indian Standard on Wind Loads
 
Creator Lakshmanan, N.
Arunachalam, S.
Gomathinayagam, S.
Selvi Rajan, S.
 
Subject Wind loads
Geometric
Dynamic analysis
 
Description The paper discusses on the suggested modifications to the wind Code, IS: 875 (Part 3) 1989, and their background information. The basic wind speed of India recommended in the existing code is re-analysed and revised by SERC in light of additional wind data made available by IMD since 1982. One of the main features of the suggested modification is to include empirical expressions for a number of parameters particularly relating to dynamic analysis. Based on recent R&D investigations in the boundary layer wind tunnel, on square and rectangular prisms of tall building models SERC has studied across wind force parameters and distributions of force spectra and developed empirical expressions for the same. Further, occupant comfort levels in tall slender buildings are addressed for which no guidelines are available in the present Code.
 
Date 2009
2009
2008
 
Type Conference paper
 
Identifier Proceedings of the Sixth Structural Engineering Convention, SEC 2008, Chennai, India, 18-20 December 2008, p.IPXXI-1-13. Jointly Organised by Structural Engineering Research Centre, Indian Institute of Technology, Anna university, Chennai.
http://hdl.handle.net/123456789/278
 
Language en