Study of the Impact of Variation in Number of Trajectories on the Collector Performance
IR@CEERI: CSIR-Central Electronics Engineering Research Institute, Pilani
View Archive InfoField | Value | |
Title |
Study of the Impact of Variation in Number of Trajectories on the Collector Performance
|
|
Creator |
Kaur, J
Latha, AM Jain, A Dheeraj, . Srivastava, V Ghosh, SK |
|
Subject |
Travelling Wave Tubes
|
|
Description |
Generally, the multi-stage depressed collector simulations have been done with the beam starting conditions of 96 electron trajectories obtained from the large signal beam-
wave interaction code – SUNRAY-3D. But, the authors had been
curious to check if the performance of the collector remains the same with increased or decreased number of electron
trajectories, which has been the motivation for carrying out this study. With this study, it has been evident that from the large signal code point of view, an optimum of 96 electron trajectories have been taken since the power, gain and electronic efficiency gets saturated beyond 96 electron trajectories. However, the performance of the collector varies highly with the increase in number of electron trajectories even beyond 96 electron trajectories.
|
|
Date |
2012
|
|
Type |
Conference or Workshop Item
PeerReviewed |
|
Format |
application/pdf
|
|
Identifier |
http://ceeri.csircentral.net/50/1/23_2012%283%29.pdf
Kaur, J and Latha, AM and Jain, A and Dheeraj, . and Srivastava, V and Ghosh, SK (2012) Study of the Impact of Variation in Number of Trajectories on the Collector Performance. In: 8th International Conference on Microwaves, Antenna, Propagation & Remote Sensing ( ICMARS - 2012) , December 11-15, 2012, ICRS, Jodhpur. (Submitted) |
|
Relation |
http://ceeri.csircentral.net/50/
|
|