Description |
This document explains the calibration procedure adopted to test the pitot-static probes, as required by HAL, Koraput. These probes (12 nos.) were calibrated in the 254 mm x 102 mm induction tunnel of the Aerodynamics Division of the Laboratory. The probe calibration factors were determined and tabulated as shown.
|
|