CSIR Central

Analysis of Premature Failure of Transmission Line Towers During Proto-Type Testing

IR@SERC: CSIR-Structural Engineering Research Centre, Chennai

View Archive Info
 
 
Field Value
 
Title Analysis of Premature Failure of Transmission Line Towers During Proto-Type Testing
 
Creator Arun Raj, M.
Jane Helena, H.
Mohan, S.J.
 
Subject Premature failure
Transmission line
Towers
Nonlinear finite element
 
Description In this paper, the failure of transmission line towers due to various reasons is analyzed by nonlinear finite element method. The finite element analyses are compared with the test results and the reasons for failure are discussed in detail.
 
Date 2009
2009
2008
 
Type Conference paper
 
Identifier National Conference on Advances in Construction Materials & Equipments, Jabalpur, India, 12-13 January, 2008, p.98-106. Organised by Civil Engineering Department, Jabalpur Engineering College, Jabalpur.
http://hdl.handle.net/123456789/183
 
Language en