CSIR Central

ACCURATE AND PRECISE E-FIELD MEASUREMENT FOR 2G AND 3G NETWORKS BASED ON IEEE STD. 1309-2013

IR@NPL: CSIR-National Physical Laboratory, New Delhi

View Archive Info
 
 
Field Value
 
Title ACCURATE AND PRECISE E-FIELD MEASUREMENT FOR 2G AND 3G NETWORKS BASED ON IEEE STD. 1309-2013
 
Creator Narang, Naina
Dubey, Satya Kesh
Negi, P. S.
Ojha, V. N.
 
Subject Engineering
Optics
 
Description This article elaborates the theoretical and measurement technique to evaluate precise and accurate electric (E)-field strength for frequency range 0.8-2.4 GHz (2G and 3G communication spectrum). The E-field using a probe is precisely measured inside an indigenously designed transverse electromagnetic (TEM) cell as per IEEE Std. 1309-2013. Key parameters for precise E- field measurement are explicated with their measurement results such as probe linearity, field distortion, and mismatch losses. E-field strength of probe has been reported 9.91 V/m with an expanded uncertainty (k approximate to 2) of +/- 0.58 V/m for +18 dBm fed power at 915 MHz frequency.
 
Publisher Wiley
 
Date 2015-07
 
Type Article
PeerReviewed
 
Format application/pdf
 
Identifier http://npl.csircentral.net/1703/1/011.pdf
Narang, Naina and Dubey, Satya Kesh and Negi, P. S. and Ojha, V. N. (2015) ACCURATE AND PRECISE E-FIELD MEASUREMENT FOR 2G AND 3G NETWORKS BASED ON IEEE STD. 1309-2013. Microwave and Optical Technology Letters, 57 (7). pp. 1645-1649. ISSN 0895-2477
 
Relation http://npl.csircentral.net/1703/