ACCURATE AND PRECISE E-FIELD MEASUREMENT FOR 2G AND 3G NETWORKS BASED ON IEEE STD. 1309-2013
IR@NPL: CSIR-National Physical Laboratory, New Delhi
View Archive InfoField | Value | |
Title |
ACCURATE AND PRECISE E-FIELD MEASUREMENT FOR 2G AND 3G NETWORKS BASED ON IEEE STD. 1309-2013
|
|
Creator |
Narang, Naina
Dubey, Satya Kesh Negi, P. S. Ojha, V. N. |
|
Subject |
Engineering
Optics |
|
Description |
This article elaborates the theoretical and measurement technique to evaluate precise and accurate electric (E)-field strength for frequency range 0.8-2.4 GHz (2G and 3G communication spectrum). The E-field using a probe is precisely measured inside an indigenously designed transverse electromagnetic (TEM) cell as per IEEE Std. 1309-2013. Key parameters for precise E- field measurement are explicated with their measurement results such as probe linearity, field distortion, and mismatch losses. E-field strength of probe has been reported 9.91 V/m with an expanded uncertainty (k approximate to 2) of +/- 0.58 V/m for +18 dBm fed power at 915 MHz frequency.
|
|
Publisher |
Wiley
|
|
Date |
2015-07
|
|
Type |
Article
PeerReviewed |
|
Format |
application/pdf
|
|
Identifier |
http://npl.csircentral.net/1703/1/011.pdf
Narang, Naina and Dubey, Satya Kesh and Negi, P. S. and Ojha, V. N. (2015) ACCURATE AND PRECISE E-FIELD MEASUREMENT FOR 2G AND 3G NETWORKS BASED ON IEEE STD. 1309-2013. Microwave and Optical Technology Letters, 57 (7). pp. 1645-1649. ISSN 0895-2477 |
|
Relation |
http://npl.csircentral.net/1703/
|
|