CSIR Central

Monitoring of corrosion of prestressing steel cables in prestressed concrete bridges

IR@CECRI: CSIR-Central Electrochemical Research Institute, Karaikudi

View Archive Info
 
 
Field Value
 
Title Monitoring of corrosion of prestressing steel cables in prestressed concrete bridges
 
Creator Suresh Bapu, R.H.
Nayak, N.U.
Srividya Rajagopalan, C.
Srinivasan, S.
Rengaswamy, N.S.
Mahadeva Iyer, Y.
 
Subject Corrosion Science and Engineering
 
Description There are many instances wherein presetressing steel in prestressed concrete has suffered sever corrosion leading to premature deterioration of bridges. Till date no reliable non-destructive test is available to monitor the condition of prestressing steel encased in cement group and high strength concrete. Attempts have been made to monitor the corrosion of prestressing steel cables by measurement of electrical resistance of the cables using accessible cable ends as terminal points. In this paper, some typical results obtained on some coastal bridges are resented. The limitations of the method are also pointed out.
 
Publisher SAEST, Karaikudi
 
Date 1988
 
Type Article
PeerReviewed
 
Format application/pdf
 
Identifier http://cecri.csircentral.net/3197/1/163-1988.pdf
Suresh Bapu, R.H. and Nayak, N.U. and Srividya Rajagopalan, C. and Srinivasan, S. and Rengaswamy, N.S. and Mahadeva Iyer, Y. (1988) Monitoring of corrosion of prestressing steel cables in prestressed concrete bridges. Transactions of SAEST, 23 (2-3). pp. 203-206.
 
Relation http://cecri.csircentral.net/3197/