CSIR Central

Performance Evaluation of 42 mm Diameter Stranded Ungalvanised Haulage Rope in a Mono-Cable Passenger Ropeway

IR@CIMFR: CSIR-Central Institute of Mining and Fuel Research, Dhanbad

View Archive Info
 
 
Field Value
 
Title Performance Evaluation of 42 mm Diameter Stranded Ungalvanised Haulage Rope in a Mono-Cable Passenger Ropeway
 
Creator Basak, Debasish
 
Subject Electrical Testing
 
Description Most common conventional method of rope condition evaluation is visual method i.e. watching the exterior strand and outer surface only. Core damage cannot be detected. To assess the rope condition, magnetic nondestructive method is the most suitable method. Periodic rope assessment is necessary to prevent rope failures and extension of rope life. Flaw detectors in the Magnetic Rope Tester detect LMA (loss in metallic area) and LF (localized faults) [1, 2]. This paper describes the performance of a haulage rope in two years.
 
Publisher Springer
 
Date 2020-10
 
Type Article
PeerReviewed
 
Identifier Basak, Debasish (2020) Performance Evaluation of 42 mm Diameter Stranded Ungalvanised Haulage Rope in a Mono-Cable Passenger Ropeway. Russian Journal of Nondestructive Testing volume, 56. pp. 592-594.
 
Relation http://cimfr.csircentral.net/2294/