CSIR Central

Conditioning and Testing of 3 MW S-Band Pulse Tunable Magnetron

IR@CEERI: CSIR-Central Electronics Engineering Research Institute, Pilani

View Archive Info
 
 
Field Value
 
Title Conditioning and Testing of 3 MW S-Band Pulse Tunable Magnetron
 
Creator Kanagraj, N
Maurya, S
Verma, RK
Chaudhary, P
Kumar , M
Yadav, V
Tillu, A
 
Subject Magnetrons
 
Description A detailed method of conditioning and testing of the 3MW S-Band pulse tunable magnetron has been discussed. As the magnetron prototypes developed are not suitable for direct operation and use in the system, certain procedures are followed to make them rugged enough to operate at the full specifications. The cathode used is a triple carbonate oxide coated and application of required voltage at the initial level may cause inefficient emission from the cathode and even damage of cathode, resulting in the end of tube life. Also the vacuum level is to be maintained inside the tubes and sufficient time is required to pump out the emitted gases from the different surfaces inside the tubes due to heating of the surfaces by electron bombardment or resistive heating.
 
Date 2018
 
Type Conference or Workshop Item
PeerReviewed
 
Format application/pdf
 
Identifier http://ceeri.csircentral.net/585/1/22-2018%283%29%281%29.pdf
Kanagraj, N and Maurya, S and Verma, RK and Chaudhary, P and Kumar , M and Yadav, V and Tillu, A (2018) Conditioning and Testing of 3 MW S-Band Pulse Tunable Magnetron. In: National Symposium on Vacuum Electronic Devices and Applications (VEDA-2018), November 22-24, 2018, IIT Guwahati, Assam, India.
 
Relation http://ceeri.csircentral.net/585/