A one year comparison of radar and pressure tide gauge at Goa, west coast of India
IR@NIO: CSIR-National Institute Of Oceanography, Goa
View Archive InfoField | Value | |
Creator |
Mehra, P.
Desai, R.G.P. Joseph, A. VijayKumar, K. Agarvadekar, Y. Luis, R. Sundar, D. Viegas, B. |
|
Date |
2009-12-08T07:00:33Z
2009-12-08T07:00:33Z 2009 |
|
Identifier |
Proceedings of the International Symposium on Ocean Electronics (SYMPOL-2009), 18-20 November 2009. eds. by: Pillai, P.R.S.; Supriya, M.H.; 173-183
http://hdl.handle.net/2264/3462 |
|
Description |
At many locations absolute pressure gauges are used to obtain sea level data. Therefore, knowledge of the other physical processes which effect the sea level measurements at the coast is very important to insert the required corrections. Data from the radar and an absolute pressure gauge are obtained over a period of one year from the test site at Verem, Goa, India. The variance of difference between the radar and absolute pressure gauge is 15.9 cm sup(2), which reduces to 5.7 and 4.0 cm sup(2) respectively, when atmospheric pressure and water density variations are introduced for obtaining sea level from an absolute pressure gauge. The regression analysis indicates that atmospheric pressure, water density and rainfall can account for the difference individually up to 71%, 33% and 27% respectively. The aim of the present study is to quantify the effects of atmospheric and oceanographic variables while measuring sea level using pressure gauges and to highlight the advantages of the radar gauge over other type of gauges with regard to easy installation, maintenance and could be given precedence in future applications
|
|
Language |
en
|
|
Publisher |
CUSAT
|
|
Rights |
At many locations absolute pressure gauges are used to obtain sea level data. Therefore, knowledge of the other physical processes which effect the sea level measurements at the coast is very important to insert the required corrections. Data from the radar and an absolute pressure gauge are obtained over a period of one year from the test site at Verem, Goa, India. The variance of difference between the radar and absolute pressure gauge is 15.9 cm sup(2), which reduces to 5.7 and 4.0 cm sup(2) respectively, when atmospheric pressure and water density variations are introduced for obtaining sea level from an absolute pressure gauge. The regression analysis indicates that atmospheric pressure, water density and rainfall can account for the difference individually up to 71%, 33% and 27% respectively. The aim of the present study is to quantify the effects of atmospheric and oceanographic variables while measuring sea level using pressure gauges and to highlight the advantages of the radar gauge over other type of gauges with regard to easy installation, maintenance and could be given precedence in future applications
|
|
Subject |
pressure gauges
sea level measurements |
|
Title |
A one year comparison of radar and pressure tide gauge at Goa, west coast of India
|
|
Type |
Conference Article
|
|