CSIR Central

4m x 8m HAL autoclave temperature and vacuum control system design

IR@NAL: CSIR-National Aerospace Laboratories, Bangalore

View Archive Info
 
 
Field Value
 
Title 4m x 8m HAL autoclave temperature and vacuum control system design
 
Creator Rao, Shankarnarayan TV
Aswath, C
Govindrajswamy, E
Krishnamurthy, V
Venkatasubramanyam, DV
Pashilkar, AA
 
Subject Electronics and Electrical Engineering
 
Description This document describes the experiments, modeling and simulation undertaken for the HAL 4 by 8 m autoclave with a view to improve the performance of its temperature and13; vacuum system. These results are presented in two parts separately.13; 13; Part I of this study include a single point and multiple point temperature models of the autoclave air temperature and component temperatures. The mathematical model has been used to design the control system parameters, in particular the PID gains for the temperature control system. In addition a setpoint hold strategy has been fine tuned to significantly improve the component temperature uniformity during cure. In Part II a mathematical model of the vacuum system has been built and validated against experimental data. Results show that the buffer tank volume in conjunction with the leakage cross-section determines the rate of pressure rise in the system. This model gives a basis for the specification of the acceptable leakage rate of the open loop vacuum system keeping in mind the frequency of control valve action desired for an on/off control scheme.
 
Publisher National Aerospace Laboratories
 
Date 2002-01
 
Type Proj.Doc/Technical Report
NonPeerReviewed
 
Format application/pdf
 
Identifier http://nal-ir.nal.res.in/2441/1/tr_pdal_0201_txt.pdf
Rao, Shankarnarayan TV and Aswath, C and Govindrajswamy, E and Krishnamurthy, V and Venkatasubramanyam, DV and Pashilkar, AA (2002) 4m x 8m HAL autoclave temperature and vacuum control system design. Technical Report. National Aerospace Laboratories, Bangalore, India.
 
Relation http://nal-ir.nal.res.in/2441/