A high intensity spark light source for schliren and direct shadow photography
IR@NAL: CSIR-National Aerospace Laboratories, Bangalore
View Archive InfoField | Value | |
Title |
A high intensity spark light source for schliren and direct shadow photography
|
|
Creator |
Srinathkumar, S
Manavalan, LS Rangan, CS |
|
Subject |
Electronics and Electrical Engineering
|
|
Description |
A high intensity light source of short duration which can be used for Schlieren and direct shadow photography is described. The source is essentially a high voltage spark which can be synchronised with the event under study or triggered with a preset delay, Provision is also made in13; the head assembly for change over to a continuous light source (tungsten filament lamp) for Schlieren studies, the optical alignment remaining the same.
|
|
Publisher |
National Aeronautical Laboratory
|
|
Date |
1964-05
|
|
Type |
Proj.Doc/Technical Report
NonPeerReviewed |
|
Format |
application/pdf
|
|
Identifier |
http://nal-ir.nal.res.in/4023/1/tn_se_5_64_p.64.pdf
Srinathkumar, S and Manavalan, LS and Rangan, CS (1964) A high intensity spark light source for schliren and direct shadow photography. Technical Report. National Aeronautical Laboratory, Bangalore, India. |
|
Relation |
http://nal-ir.nal.res.in/4023/
|
|