Failure analysis of cracked connecting piece of BFW preheater
IR@NAL: CSIR-National Aerospace Laboratories, Bangalore
View Archive InfoField | Value | |
Title |
Failure analysis of cracked connecting piece of BFW preheater
|
|
Creator |
Venkataswamy, MA
Sujata, M Parameswara, MA Bhaumik, SK |
|
Subject |
Aeronautics (General)
Chemistry and Materials (General) |
|
Description |
It was reported that the stainless steel elbow connecting two heat exchangers cracked within two months of service. Analysis revealed that a number of cracks nucleated in the vicinity of the weld and propagated radially. Microstructural and fractographic analyses suggest that the failure was due to stress corrosion cracking (SCC). High concentration of KOH in the process gas was responsible for the SCC. A detailed analysis of the failure is presented in the report.
|
|
Publisher |
National Aerospace Laboratories
|
|
Date |
2004
|
|
Type |
Proj.Doc/Technical Report
NonPeerReviewed |
|
Identifier |
Venkataswamy, MA and Sujata, M and Parameswara, MA and Bhaumik, SK (2004) Failure analysis of cracked connecting piece of BFW preheater. Project Report. National Aerospace Laboratories, Bangalore.
|
|
Relation |
http://nal-ir.nal.res.in/9565/
|
|