Analysis of failed Merox off gas line to crude heater
IR@NAL: CSIR-National Aerospace Laboratories, Bangalore
View Archive InfoField | Value | |
Title |
Analysis of failed Merox off gas line to crude heater
|
|
Creator |
Venkataswamy, MA
Sujata, M Parameswara, MA Bhaumik, SK |
|
Subject |
Aeronautics (General)
Chemistry and Materials (General) |
|
Description |
Evidences suggest that the Merox gas off line to crude heater has failed by gradual loss of material from the inner surface of the tube in localized regions by corrosion. It appears most probable that deposition of scales resulted in increase in local temperature beyond 7230C. The high quantity of S present in the scale led to localized sulfide corrosion.
|
|
Publisher |
National Aerospace Laboratories
|
|
Date |
2004
|
|
Type |
Proj.Doc/Technical Report
NonPeerReviewed |
|
Identifier |
Venkataswamy, MA and Sujata, M and Parameswara, MA and Bhaumik, SK (2004) Analysis of failed Merox off gas line to crude heater. Project Report. National Aerospace Laboratories, Bangalore.
|
|
Relation |