CSIR Central

Comparison of bolted joints with two different clearance types

IR@NISCAIR: CSIR-NISCAIR, New Delhi - ONLINE PERIODICALS REPOSITORY (NOPR)

View Archive Info
 
 
Field Value
 
Creator Esendemir, Ümran
Öndürücü, Ayşe
 
Date 2011-10-18T10:34:01Z
2011-10-18T10:34:01Z
2011-08
 
Identifier 0975-1017 (Online); 0971-4588 (Print)
http://hdl.handle.net/123456789/12894
 
Description 283-292
In this study, bearing strengths of bolted joints with different clearances are compared. Woven-glass-epoxy prepreg composites are tested under two different bolt-bearing conditions. The geometry of the samples for bolted joints is suitably varied in order to find the limit for width-to-diameter (<i style="">W</i>/<i style="">d</i>) and edge distance-to-diameter ratios (<i style="">E</i>/<i style="">d</i>), which are necessary to avoid unsafe failure modes. Damage progression is examined using scanning electron microscope (SEM) on specimens with mixed (bearing+net tension) mode for different percentages of their ultimate failure load. It is observed that the clearance between the bolt and hole has an important influence on the failure load of mechanically fastened joints.
 
Language en_US
 
Publisher NISCAIR-CSIR, India
 
Rights <img src='http://nopr.niscair.res.in/image/cc-license-sml.png'> <a href='http://creativecommons.org/licenses/by-nc-nd/2.5/in' target='_blank'>CC Attribution-Noncommercial-No Derivative Works 2.5 India</a>
 
Source IJEMS Vol.18(4) [August 2011]
 
Subject Bolted-joints
Failure analysis
Scanning electron microscopy (SEM)
 
Title Comparison of bolted joints with two different clearance types
 
Type Article