CSIR Central

Improved Microcombustion Technique for Carbon-HydrogenEstimation in Perhydro-polycyclic Compounds.I Steroids and Triterpenoids.

IR@CDRI: CSIR-Central Drug Research Institute, Lucknow

View Archive Info
 
 
Field Value
 
Creator Saran, J
Khanna, P N
Banerji, Sukriti
Zaidi, S B N
 
Date 2010-04-29T04:59:06Z
2010-04-29T04:59:06Z
1968
 
Identifier Mikrochimica Acta [Wien] 1968, 1124,1128
http://hdl.handle.net/123456789/546
 
Description Polycyclic compounds are known to give low carbon values by the conventional microanalytical methodl. During routine analysis over the last 15 years it has been found that perhydropolycyclic compounds, particularly those having angular methyl groups, give erroneous results using copper oxide or copper oxide-lead chromate filling. Analytical data of steroids, triterpenoids and similar compounds of natural origin reported in the literature frequently show more than 0.5 per cent deviation in carbon values2-11. In general the values are less for carbon than the calculated ones. It was, therefore, of interest to improve upon the existing methods and the present communication deals with such an attempt.
 
Format 1902714 bytes
application/pdf
 
Language en
 
Subject Carbon-Hydrogen
Perhydro-polycyclic Compounds
Microcombustion Technique
triterpenoids
 
Title Improved Microcombustion Technique for Carbon-HydrogenEstimation in Perhydro-polycyclic Compounds.I Steroids and Triterpenoids.
 
Type Article