CSIR Central

Air Leakage Through Underground Ventilation Structures with Special Reference to Isolation Stoppings

IR@CIMFR: CSIR-Central Institute of Mining and Fuel Research, Dhanbad

View Archive Info
 
 
Field Value
 
Title Air Leakage Through Underground Ventilation Structures with Special Reference to Isolation Stoppings
 
Creator Varma, N. K.
Singh, Arvind Kumar
Pandey, J.K.
Gupta, M.L.
 
Subject Mine Ventilation
 
Description Between the fan and the face in a mine a lot of air is lost through leakage at stoppings, doors, air-crossings etc. so that a much larger quantity of air has to be circulated by the fan in order that the stipulated quantity of air reaches the face. In the present work we have developed a mathematical procedure and applied to determine average resistance of a stopping in a row. To affect the necessary iterative calculations, a computer program STOPLEAK was developed and used for analysing stopping leakages. Air leakage through doors and air crossing was also measured by conventional method in three mines viz. Moira (Jambad and Kajora seams) Sodepur (Dishergerh seam) and Kuardi 11/12 pits (Niga seam) colleries.
 
Publisher Books and Journals Private Ltd.,
 
Date 1997-04
 
Type Article
PeerReviewed
 
Format application/pdf
 
Identifier http://cimfr.csircentral.net/679/1/5.%20Air%20leakage%20through%20underground%20ventilation%20structures%20with%20special%20reference%20to%20isolation%20stopping.pdf
Varma, N. K. and Singh, Arvind Kumar and Pandey, J.K. and Gupta, M.L. (1997) Air Leakage Through Underground Ventilation Structures with Special Reference to Isolation Stoppings. Journal of Mines, Metals & Fuels, 45 (4). pp. 103-106. ISSN 0022-2755
 
Relation http://cimfr.csircentral.net/679/